Relevance of CO2-based IAQ indicators: Feedback from long-term monitoring of three nearly zero-energy houses - Intégration et Coopération dans l'Espace Européen - Etudes Européennes - EA 2291 Accéder directement au contenu
Article Dans Une Revue Journal of Building Engineering Année : 2021

Relevance of CO2-based IAQ indicators: Feedback from long-term monitoring of three nearly zero-energy houses

Alexander Rieser
  • Fonction : Auteur
Rainer Pfluger
  • Fonction : Auteur
Alexandra Troi
  • Fonction : Auteur
Daniel Herrera-Avellanosa
  • Fonction : Auteur
Kirsten Engelund Thomsen
Jørgen Rose
Zeynep Durmuş Arsan
Gulden Gokcen Akkurt
  • Fonction : Auteur
Gerhard Kopeinig
  • Fonction : Auteur
Daniel Chung
  • Fonction : Auteur
Najwa Kanama
  • Fonction : Auteur
Daria Zukowska
Gabriel Rojas
Esfand Burman
Jelle Laverge
Guangyu Cao
Léna Migne
  • Fonction : Auteur
Mallory Bobee
  • Fonction : Auteur
Valérie Leprince
  • Fonction : Auteur
Max Sherman
  • Fonction : Auteur
Iain Walker
  • Fonction : Auteur
Claire-Sophie Coeudevez
  • Fonction : Auteur
Suzanne Déoux
  • Fonction : Auteur
Sandra Berlin
  • Fonction : Auteur
Alexis Huet
  • Fonction : Auteur
Sylvain Berthault
  • Fonction : Auteur
Damien Labaume
  • Fonction : Auteur
Elsa Pastor
F. Rémi Carrié
  • Fonction : Auteur

Résumé

Nowadays, many countries include requirements for building airtightness in their current national regulations or energy-efficiency programs, mainly for concern about reducing building energy consumption due to air leakage. Moreover, more and more countries impose a mandatory justification with an air leakage measurement at building commissioning. Therefore, the uncertainty of the measurements results has become a key concern in several countries over the past year. More specifically, the influence of wind speed has been identified as one of the major sources of error on the measurement result. The goal of this paper is to present the experimental facility we design and built to improve the uncertainty estimates and the measurement protocol based on model scale experiments in controlled laboratory conditions. We first present the similarity criteria we identified for our model scale experiment. Secondly, we present the experimental design. Finally, we characterize the wind speed inside the wind tunnel and we present the preliminary results regarding the reproduction of fan pressurization tests on the model for different leakage distributions.

Dates et versions

hal-03669489 , version 1 (16-05-2022)

Identifiants

Citer

María José Rueda López, Benjamin Golly, Michel Ondarts, Frédéric Wurtz, Evelyne Gonze, et al.. Relevance of CO2-based IAQ indicators: Feedback from long-term monitoring of three nearly zero-energy houses. Journal of Building Engineering, 2021, 44 (6), pp.103350. ⟨10.1016/j.jobe.2021.103350⟩. ⟨hal-03669489⟩